Healthcare

Healthcare MEP Estimating

Healthcare MEP estimating covers medical gas, infection control HVAC, and redundant power systems priced to FGI Guidelines and ASHRAE 170, built for hospitals and medical office projects. Most estimates are delivered in 24-48 hours, with pricing above standard commercial rates due to code complexity. Estimates are billed at $30-$45 per hour.

Medical gas, infection control HVAC, and redundant power, priced to FGI Guidelines and ASHRAE 170.

Healthcare MEP work carries more regulatory weight per square foot than almost any other building type, and a generic commercial estimate applied to a hospital or clinic will miss scope that's non-negotiable under code. Medical gas systems, oxygen, medical air, vacuum, and nitrous oxide where applicable, are taken off as their own scope entirely separate from standard plumbing: piping by gas type and size, station outlets by room, alarm panels, and source equipment including manifolds, bulk tanks, medical air compressors, and vacuum pumps. Every component is priced against NFPA 99 requirements for the specific gas type and the risk category of the space it serves, since a Category 1 risk space like an operating room carries different system redundancy requirements than a Category 3 space like an exam room.

Infection control drives HVAC design and cost in healthcare facilities more than almost any other factor, and ASHRAE 170 sets the specific requirements we estimate against: minimum air change rates, pressure relationships (positive for operating rooms and protective environment rooms, negative for airborne infection isolation rooms), and filtration levels, all specified space by space rather than as a single building average. We size and price air handling equipment, ductwork, and terminal devices against these space-specific requirements, since treating an entire hospital floor as one HVAC zone with a blended average load would misprice both the mechanical equipment and the ductwork distribution serving high-requirement spaces like ORs and isolation rooms.

Redundant power is where healthcare electrical estimating earns its complexity. FGI Guidelines and NEC Article 517 require essential electrical systems organized into life safety, critical, and equipment branches, each with defined transfer time requirements and connected loads, backed by emergency generators and, in critical care areas, UPS systems for equipment that can't tolerate even the brief transfer time to generator power. We scope generators, automatic transfer switches, and UPS systems against the specific branch requirements for each department, operating rooms and ICUs carry different critical branch loads than general patient floors, rather than sizing emergency power as a flat percentage of normal power. The result is a line-item estimate that reflects what a healthcare facility actually has to install to pass life safety plan review, not a commercial building estimate with a healthcare label on it.

What Makes This Industry Unique

  • Medical gas systems require separate takeoff and NFPA 99 risk-category-based pricing
  • ASHRAE 170 sets space-specific air change, pressure, and filtration requirements
  • Essential electrical systems require life safety, critical, and equipment branch separation
  • FGI Guidelines and NEC Article 517 govern healthcare-specific system redundancy
  • Infection control requirements vary dramatically between department types in the same building

Key MEP Systems for This Building Type

  • Medical gas: oxygen, medical air, vacuum, and nitrous oxide piping and source equipment
  • Space-specific HVAC: pressure relationships and air change rates per ASHRAE 170
  • Essential electrical system branches: life safety, critical, equipment
  • Emergency generators, automatic transfer switches, and UPS systems
  • Infection control features: HEPA filtration, anterooms, isolation room pressurization

24-48 Hour Turnaround on standard requests.

Common Questions

Do you estimate medical gas systems for healthcare projects?

Yes. We take off medical gas piping, outlets, alarm panels, and source equipment (manifolds, bulk tanks, medical air compressors, vacuum pumps) as a distinct scope from standard plumbing, priced to NFPA 99 requirements for the specific gas type and risk category of the space.

How does ASHRAE 170 affect a healthcare HVAC estimate?

ASHRAE 170 sets minimum air change rates, pressure relationships, and filtration requirements by space type, operating rooms, isolation rooms, and patient rooms each carry different requirements, and we size and price HVAC equipment and ductwork against the specific space-by-space requirements rather than a single building-wide average.

Do you price redundant power systems like generators and UPS for hospitals?

Yes. Emergency generators, automatic transfer switches, and UPS systems are scoped per the essential electrical system branches that FGI Guidelines and NEC Article 517 require for healthcare occupancies, with critical, life safety, and equipment branches priced as distinct circuits.

Ready to Get Started?

Submit your healthcare project drawings for a code-grounded MEP estimate.